Fire protection, engineered end to end.
Turnkey fire system engineering for commercial and industrial property: assessment, design, installation and maintenance of sprinkler, suppression and detection systems.
Designed for
the worst day.
- 01 Design
Engineered to the hazard.
Head layout, spacing, pipe sizes and hydraulic calculations are matched to the occupancy and risk, in line with ASIB, NFPA and the National Building Regulations.
- 02 Install & charge
Installed, filled, waiting.
Mains, branch lines and pendant heads are installed and the wet-pipe system is charged with water under pressure, ready at every head.
- 03 Fire
Heat rises to the ceiling.
Hot gases collect under the roof. Each head's glass bulb is a heat-sensitive element, rated to operate at a set temperature.
- 04 Activation
Only the heads that need to.
The bulb shatters, the seal drops and water discharges onto the fire. Heads operate individually, so only those over the fire open.
- 05 Control
Flow, alarm, control.
Water flow trips the alarm valve and flow switch, the alarm sounds and the fire pump maintains pressure while the fire is controlled.
- 06 Maintain
Ready for the next time.
Operated heads are replaced, the system is restored, and routine inspection and maintenance keep it compliant.
Assessed, designed,
installed, maintained.
- Systems
- Wet · dry · pre-action · deluge · foam · water mist
- Also
- Suppression and smoke detection
- Standards
- In line with ASIB, NFPA and the National Building Regulations
- Lifecycle
- Assessment · design · installation · maintenance
From inspection to maintenance.
One team responsible for the system across its life, so design intent, installation and maintenance stay aligned.
- 01 · Assess
Inspect
Complete inspection of the property and existing systems against legislative requirements.
- 02 · Design
Engineer
Specifications, plans, layouts, schematics and hydraulic calculations for a system matched to the risk.
- 03 · Install
Install
Installation in line with ASIB, NFPA and the National Building Regulations.
- 04 · Maintain
Maintain
Ongoing maintenance to keep systems compliant and ready to operate.
Six system types, matched to the hazard.
| System | Principle |
|---|---|
| Wet pipe | Pipes permanently charged with water; heads discharge individually on activation. |
| Dry pipe | Pipes charged with air or nitrogen; for areas exposed to freezing. |
| Pre-action | Detection must operate before water enters the pipework; protects sensitive spaces. |
| Deluge | Open heads discharge simultaneously across a zone on detection. |
| Foam | Foam concentrate added to water for flammable-liquid hazards. |
| Water mist | Fine droplets cool and suppress with reduced water use. |
Fire suppression systems
Suppression with integrated detection and alarm devices.
Smoke detection
Early-warning detection, integrated with sprinkler protection.
Custom fire protection
Systems designed around the specific risk of a commercial or industrial property.
Products
Supply of fire protection equipment for the systems Redsafe designs and maintains.
Designed and installed to recognised rules.
Years of collective industry experience across the fire systems team.
Stages under one team: inspect, engineer, install, maintain.
Rule sets worked to: ASIB, NFPA, FM, SANS and the National Building Regulations.
Sprinkler system types designed and installed.
Is your system compliant?
Book an inspection of your existing fire protection, or send drawings for a new installation.